Espressif Systems /ESP32-P4 /MCPWM0 /FH2_CFG1

Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text

Interpret as FH2_CFG1

31 2827 2423 2019 1615 1211 87 43 0 0 0 0 0 0 0 0 00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 (TZ_CLR_OST)TZ_CLR_OST 0TZ_CBCPULSE 0 (TZ_FORCE_CBC)TZ_FORCE_CBC 0 (TZ_FORCE_OST)TZ_FORCE_OST

Description

Software triggers for fault handler actions configuration register

Fields

TZ_CLR_OST

Configures the generation of software one-shot mode action clear. A toggle (software negate its value) triggers a clear for on going one-shot mode action.

TZ_CBCPULSE

Configures the refresh moment selection of cycle-by-cycle mode action.\0: Select nothing, will not refresh\Bit0 is set to 1: TEZ\Bit1 is set to 1: TEP

TZ_FORCE_CBC

Configures the generation of software cycle-by-cycle mode action. A toggle (software negate its value) triggers a cycle-by-cycle mode action.

TZ_FORCE_OST

Configures the generation of software one-shot mode action. A toggle (software negate its value) triggers a one-shot mode action.

Links

() ()